49 research outputs found

    Atrial defibrillation with a transvenous lead A randomized comparison of active can shocking pathways

    Get PDF
    AbstractOBJECTIVESThe purpose of this study was to compare transvenous atrial defibrillation thresholds with lead configurations consisting of an active left pectoral electrode and either single or dual transvenous coils.BACKGROUNDLow atrial defibrillation thresholds are achieved using complex lead systems including coils in the coronary sinus. However, the efficacy of more simple ventricular defibrillation leads with active pectoral pulse generators to defibrillate atrial fibrillation (AF) is unknown.METHODSThis study was a prospective, randomized assessment of shock configuration on atrial defibrillation thresholds in 32 patients. The lead system was a dual coil Endotak DSP lead with a left pectoral pulse generator emulator. Shocks were delivered either between the right ventricular coil and an active can in common with the proximal atrial coil (triad) or between the atrial coil and active can (transatrial).RESULTSDelivered energy at defibrillation threshold was 7.1 ± 6.0 J in the transatrial configuration and 4.0 ± 4.2 J in the triad configuration (p < 0.005). Moreover, a low threshold (≤3 J) was observed in 69% of subjects in the triad configuration but only 47% in the transatrial configuration. Peak voltage and shock impedance were also lowered significantly in the triad configuration. Left atrial size was the only clinical predictor of the defibrillation theshold (r = 0.57, p < 0.002).CONCLUSIONSThese results indicate that low atrial defibrillation thresholds can be achieved using a single-pass transvenous ventricular defibrillation lead with a conventional ventricular defibrillation pathway. These data support the development of the combined atrial and ventricular defibrillator system

    Image-based view-angle independent cardiorespiratory motion gating and coronary sinus catheter tracking for x-ray-guided cardiac electrophysiology procedures

    Get PDF
    Determination of the cardiorespiratory phase of the heart has numerous applications during cardiac imaging. In this article we propose a novel view-angle independent near-real time cardiorespiratory motion gating and coronary sinus (CS) catheter tracking technique for x-ray fluoroscopy images that are used to guide cardiac electrophysiology procedures. The method is based on learning CS catheter motion using principal component analysis and then applying the derived motion model to unseen images taken at arbitrary projections, using the epipolar constraint. This method is also able to track the CS catheter throughout the x-ray images in any arbitrary subsequent view. We also demonstrate the clinical application of our model on rotational angiography sequences. We validated our technique in normal and very low dose phantom and clinical datasets. For the normal dose clinical images we established average systole, end-expiration and end-inspiration gating success rates of 100%, 85.7%, and 92.3%, respectively. For very low dose applications, the technique was able to track the CS catheter with median errors not exceeding 1 mm for all tracked electrodes. Average gating success rates of 80.3%, 71.4%, and 69.2% were established for the application of the technique on clinical datasets, even with a dose reduction of more than 10 times. In rotational sequences at normal dose, CS tracking median errors were within 1.2 mm for all electrodes, and the gating success rate was 100%, for view angles from RAO 90° to LAO 90°. This view-angle independent technique can extract clinically useful cardiorespiratory motion information using x-ray doses significantly lower than those currently used in clinical practice

    Novel system for real-time integration of 3-D echocardiography and fluoroscopy for image-guided cardiac interventions: Preclinical validation and clinical feasibility evaluation

    Get PDF
    © 2015 IEEE. Real-time imaging is required to guide minimally invasive catheter-based cardiac interventions. While transesophageal echocardiography allows for high-quality visualization of cardiac anatomy, X-ray fluoroscopy provides excellent visualization of devices. We have developed a novel image fusion system that allows real-time integration of 3-D echocardiography and the X-ray fluoroscopy. The system was validated in the following two stages: 1) preclinical to determine function and validate accuracy; and 2) in the clinical setting to assess clinical workflow feasibility and determine overall system accuracy. In the preclinical phase, the system was assessed using both phantom and porcine experimental studies. Median 2-D projection errors of 4.5 and 3.3 mm were found for the phantom and porcine studies, respectively. The clinical phase focused on extending the use of the system to interventions in patients undergoing either atrial fibrillation catheter ablation (CA) or transcatheter aortic valve implantation (TAVI). Eleven patients were studied with nine in the CA group and two in the TAVI group. Successful real-time view synchronization was achieved in all cases with a calculated median distance error of 2.2 mm in the CA group and 3.4 mm in the TAVI group. A standard clinical workflow was established using the image fusion system. These pilot data confirm the technical feasibility of accurate real-time echo-fluoroscopic image overlay in clinical practice, which may be a useful adjunct for real-time guidance during interventional cardiac procedures

    A statistical method for retrospective cardiac and respiratory motion gating of interventional cardiac x-ray images

    Get PDF
    Purpose: Image-guided cardiac interventions involve the use of fluoroscopic images to guide the insertion and movement of interventional devices. Cardiorespiratory gating can be useful for 3D reconstruction from multiple x-ray views and for reducing misalignments between 3D anatomical models overlaid onto fluoroscopy. Methods: The authors propose a novel and potentially clinically useful retrospective cardiorespiratory gating technique. The principal component analysis (PCA) statistical method is used in combination with other image processing operations to make our proposed masked-PCA technique suitable for cardiorespiratory gating. Unlike many previously proposed techniques, our technique is robust to varying image-content, thus it does not require specific catheters or any other optically opaque structures to be visible. Therefore, it works without any knowledge of catheter geometry. The authors demonstrate the application of our technique for the purposes of retrospective cardiorespiratory gating of normal and very low dose x-ray fluoroscopy images. Results: For normal dose x-ray images, the algorithm was validated using 28 clinical electrophysiology x-ray fluoroscopy sequences (2168 frames), from patients who underwent radiofrequency ablation (RFA) procedures for the treatment of atrial fibrillation and cardiac resynchronization therapy procedures for heart failure. The authors established end-systole, end-expiration, and end-inspiration success rates of 97.0%, 97.9%, and 97.0%, respectively. For very low dose applications, the technique was tested on ten x-ray sequences from the RFA procedures with added noise at signal to noise ratio (SNR) values of √50, √10, √8, √6, √5, √2 and √1 to simulate the image quality of increasingly lower dose x-ray images. Even at the low SNR value of √2, representing a dose reduction of more than 25 times, gating success rates of 89.1%, 88.8%, and 86.8% were established. Conclusions: The proposed technique can therefore extract useful information from interventional x-ray images while minimizing exposure to ionizing radiation. © 2014 American Association of Physicists in Medicine

    Benefits, Barriers and Enablers of Breastfeeding: Factor Analysis of Population Perceptions in Western Australia

    Get PDF
    Objective: The objective of this study was to investigate knowledge and community perceptions of breastfeeding in Western Australia using a factor analysis approach. Methods: Data were pooled from five Nutrition Monitoring Survey Series which included information on breastfeeding from 4,802 Western Australian adults aged 18–64 years. Tetrachoric factor analysis was conducted for data reduction and significant associations identified using logistic, ordinal and poisson regression analyses. Results: Four factors were derived for benefits (it’s natural, good nutrition, good for the baby, and convenience), barriers (breastfeeding problems, poor community acceptability, having to go back to work, and inconvenience) and for enablers (breastfeeding education, community support, family support and not having to work).As assessed by standardized odds ratios the most important covariates across benefit factors were: importance of breastfeeding (ORs range from 1.22–1.44),female gender (ORs range from 0.80 to 1.46), being able to give a time for how long a baby should be breastfed (ORs range from 0.96 to 1.27) and education (less than high school to university completion) (ORs range from 0.95 to 1.23); the most important covariate across barrier factors was being able to give a time for how long a baby should be breastfed (ORs range from 0.89 to 1.93); and the most important covariates across all enabling factors were education (ORs range from 1.14 to1.32) and being able to give a time for how long a baby should be breastfed (ORs range from 1.17 to 1.42).Conclusions: Being female, rating breastfeeding as important, believing that babies should be breastfed for a period of time and education accounted for most of the statistically significant associations. The differences between male and female perceptions require investigation particularly in relation to returning to work

    A survey on worries of pregnant women - testing the German version of the Cambridge Worry Scale

    Get PDF
    Background: Pregnancy is a transition period in a woman's life characterized by increased worries and anxiety. The Cambridge Worry Scale (CWS) was developed to assess the content and extent of maternal worries in pregnancy. It has been increasingly used in studies over recent years. However, a German version has not yet been developed and validated. The aim of this study was (1) to assess the extent and content of worries in pregnancy on a sample of women in Germany using a translated and adapted version of the Cambridge Worry Scale, and (2) to evaluate the psychometric properties of the German version. Methods: We conducted a cross-sectional study and enrolled 344 pregnant women in the federal state of Baden-Wurttemberg, Germany. Women filled out structured questionnaires that contained the CWS, the Spielberger-State-Trait-Anxiety Inventory (STAI), as well as questions on their obstetric history. Antenatal records were also analyzed. Results: The CWS was well understood and easy to fill in. The major worries referred to the process of giving birth (CWS mean value 2.26) and the possibility that something might be wrong with the baby (1.99), followed by coping with the new baby (1.57), going to hospital (1.29) and the possibility of going into labour too early (1.28). The internal consistency of the scale (0.80) was satisfactory, and we found a four-factor structure, similar to previous studies. Tests of convergent validity showed that the German CWS represents a different construct compared with state and trait anxiety but has the desired overlap. Conclusions: The German CWS has satisfactory psychometric properties. It represents a valuable tool for use in scientific studies and is likely to be useful also to clinicians
    corecore